logo
Rumah Produknon-merusak pengujian peralatan

HCDX-C280DC DC Demagnetization and Magnetization Particle Inspection Coil

Sertifikasi
Cina HUATEC  GROUP  CORPORATION Sertifikasi
Cina HUATEC  GROUP  CORPORATION Sertifikasi
Ulasan pelanggan
berbagai macam produk NDT, kita bisa mendapatkan semua dalam kelompok huatec. Kami lebih suka membeli dari mereka. Rudolf Shteinman Rusia

—— Rudolf Shteinman

Saya suka layanannya, responsnya sangat cepat, kerja profesional. Aret Turki

—— Aret Kaya

huatec hardness tester, kualitas sangat baik, kami sangat puas dengan portable hardness tester RHL-50. Kumaren Govender Sotuth Afrika

—— Kumaren Govender

I 'm Online Chat Now

HCDX-C280DC DC Demagnetization and Magnetization Particle Inspection Coil

HCDX-C280DC DC Demagnetization and Magnetization Particle Inspection Coil
HCDX-C280DC DC Demagnetization and Magnetization Particle Inspection Coil HCDX-C280DC DC Demagnetization and Magnetization Particle Inspection Coil

Gambar besar :  HCDX-C280DC DC Demagnetization and Magnetization Particle Inspection Coil

Detail produk:
Tempat asal: Cina
Nama merek: HUATEC
Sertifikasi: CE
Nomor model: HCDX-C280DC
Syarat-syarat pembayaran & pengiriman:
Kuantitas min Order: 1 set
Kemasan rincian: Kemasan karton
Waktu pengiriman: 7-10 hari kerja setelah menerima pembayaran Anda
Syarat-syarat pembayaran: T/T, Western Union, Paypal
Menyediakan kemampuan: 10 set/bulan

HCDX-C280DC DC Demagnetization and Magnetization Particle Inspection Coil

Deskripsi
Catu daya: AC200-240V 50 / 60Hz Kekuatan Medan Magnet Pusat: > 450GS (batas sebenarnya adalah 508GS).
Arus demagnetisasi: 9.8A-0 Tingkat beban sementara: 10%-20%
Menyoroti:

DC demagnetization inspection coil

,

magnetization particle testing equipment

,

HCDX-C280DC NDT inspection coil

HCDX-C280DC DC Demagnetization and Magnetization Particle Inspection Coil 


I. Product Overview

*Product Name: DC Magnetization and Demagnetization Coil

*Product Model: HCDX-C280DC

*Main Application: This product is a key component of a magnetic particle inspection equipment, used for magnetizing (magnetizing) and demagnetizing iron magnetic workpieces to detect defects on the surface or near the surface of the workpiece.

*Product Features: Based on the factory test report, this equipment has the characteristics of a strong central magnetic field (up to 508GS or above), excellent demagnetization effect (up to 0.1mT), stable operation, and safety and reliability.


II. Technical Parameters

The following parameters have been tested and verified to be qualified upon leaving the factory, representing the performance indicators of the equipment under normal operating conditions:

Magnetization Current When the working voltage is AC230V, the maximum current is 9.8A (the recommended adjustment range is 0-8A. Excessive current usage may cause the coil to overheat).
Demagnetization Current 9.8A - 0
Central Magnetic Field Strength

> 450GS (the actual limit is 508GS).

Error Rate of Axial Magnetization Current ≤ ±10% (the actual measurement is < +3%), ensuring uniform magnetization
Demagnetization Effect

Residual Magnetic Field ≤ 0.2mT (the actual measurement is 0.1mT).

Overall Insulation Resistance ≥ 2MΩ (the actual measurement is 5.2MΩ), ensuring electrical safety
Sensitivity

Can be calibrated using A1 15/50 standard test pieces, with clear display.

Temperature Rise

Under a load rate of 10%-20%, after continuous operation for 4 hours, the temperature rise complies with the JB/T8290-2011 standard.

Operating Noise < 60dB


III. Operating Steps

(1) Pre-operation Inspection

*Safety Check: Ensure that the equipment is properly grounded and check the power cord and output cable for integrity. Observe if the equipment surface is damaged and confirm that the safety warning signs are clearly visible.

*Accessory Check: Confirm that all accessories (such as connection cables, connectors, etc.) are complete and in good condition.

*Environmental Confirmation: Ensure that the working environment is dry and clean, and there are no flammable or explosive items.

(2) Charging Operation Procedure

*Connect the workpiece: Firmly connect the equipment's output end to the workpiece to be inspected.

*Parameter Setting: Based on the material, specifications, and inspection standards of the workpiece, set an appropriate magnetization current within the range of 0-8A. It is recommended to start with a lower current.

*Start Charging: Press the charging button, and the equipment will magnetize the workpiece. The magnetization time is usually very short (a few seconds).

*Apply Magnetic Suspension: Spray magnetic suspension on the surface of the workpiece during or immediately after magnetization.

*Inspect Defects: Under appropriate lighting, observe if there are magnetic traces on the workpiece surface. You can use A1 15/50 test pieces to verify if the sensitivity is up to standard.

(3) Demagnetization Operation Procedure

*Demagnetize the workpiece: Ensure that the workpiece is in the center of the coil.

*Start Demagnetization: Press the demagnetization button, and the equipment will automatically perform the demagnetization operation. The demagnetization is complete when the current meter pointer returns to zero.

*Effect Verification: Use a magnetic field measurement instrument (such as a gauss meter) to detect the residual magnetic field at key parts of the workpiece. It should not exceed 0.2mT (the actual measurement usually reaches 0.1mT).


IV. Precautions and Maintenance

*Safety Warning:

Ensure reliable grounding during operation to prevent electric shock.

The equipment will generate a strong magnetic field. People with pacemakers, implanted medical devices, and pregnant women should stay away.

Avoid touching the high-voltage terminals directly when the equipment is running.

*Operation Tips:

Do not operate for a long time exceeding the maximum magnetization current (8A) to avoid damaging the equipment.

When working continuously, pay attention to the load duration rate of the equipment (10%-20%), and avoid excessive temperature rise due to long-term high-load operation. It is recommended to stop the machine for cooling or reduce the load rate after 2 hours of operation.

Keep the equipment clean and dry, and regularly check the insulation performance.

*Daily Maintenance:

Regularly inspect the appearance spraying quality. If there is any damage, handle it promptly to prevent rusting.

Regularly check whether all electrical instruments and operating systems are operating normally.

When not in use for a long time, it should be stored in a dry and well-ventilated place.


V. Fault Resolution (Brief)

Phenomenon

Possible reasons

Suggested measures

Unable to magnetize / demagnetize

The power supply is not connected and the wiring is not properly connected.

Check the power supply, switch and connection cables

Insufficient central magnetic field

The magnetizing current setting is too low.

Properly increase the current (within the range of 8A)

The residual magnetic field is very strong after demagnetization.

The demagnetization procedure was not fully carried out or the material of the workpiece is special.

Re-perform the demagnetization operation, or contact the technician.

Abnormal noise from the equipment

Internal components are loose.

Stop the machine immediately and contact a professional repair person.

 

HCDX-C280DC DC Demagnetization and Magnetization Particle Inspection Coil  0

HCDX-C280DC DC Demagnetization and Magnetization Particle Inspection Coil  1

Rincian kontak
HUATEC GROUP CORPORATION

Kontak Person: Ms. Shifen Yuan

Tel: 8610 82921131,8618610328618

Faks: 86-10-82916893

Mengirimkan permintaan Anda secara langsung kepada kami (0 / 3000)